How to fix PCDE error on INVT CHV180-004G-4 Inverter?
- RRichard OconnorSep 12, 2025
If your INVT Inverter displays 'PCDE', it is because the encoder signal wire was connected wrong. Adjust encoder wiring.

How to fix PCDE error on INVT CHV180-004G-4 Inverter?
If your INVT Inverter displays 'PCDE', it is because the encoder signal wire was connected wrong. Adjust encoder wiring.
What does PCE mean on my INVT CHV180-004G-4 Inverter?
If your INVT Inverter displays 'PCE', it could be due to a broken encoder signal wire (inspect encoder connection) or a damaged encoder (inspect whether the encoder output signal or not).
Why is my INVT CHV180-004G-4 showing OV3 error?
If your INVT Inverter displays 'OV3', it could be due to abnormal input voltage changes (install input reactor) or high load inertia (add proper braking kits).
What does EEP error mean on INVT CHV180-004G-4?
If your INVT Inverter displays 'EEP', it could be due to a read/write fault of control parameters (press STOP/RST to reset) or EEPROM damage (ask for support).
What causes TE error on INVT CHV180-004G-4 Inverter?
If your INVT Inverter displays 'TE', it could be due to the motor capacity not being compatible with that of the inverter (change the model of the inverter), improper setting of motor rated parameters (set the rated parameters according to the nameplate of the motor), a large offset between the parameters in the autotuning and the standard parameters (empty the motor and reidentify), or overtime of autotuning (check motor’s wiring and the parameters setting).
What to do if my INVT CHV180-004G-4 Inverter displays OH1?
If your INVT Inverter displays 'OH1', it indicates a sudden overcurrent. Refer to the overcurrent solution. Other causes include a short-circuited output phase (reconfigure), a damaged ventilation duct or fan (clear the duct and change the fan), high ambient temperature (reduce it), loose wiring on the control board (check and rewire), damage to the assistant circuit causing undervoltage (ask for support), a direct bridge arm issue in the power module (ask for support), or an abnormal control board (ask for support).
What does CE error mean on INVT Inverter?
If your INVT Inverter displays 'CE', it could be caused by an improper baud rate setting (select proper baud rate), receiving wrong data (press STOP/RST to reset and ask for support), or communication being interrupted for a long time (check communication devices and signals).
What to do if my INVT CHV180-004G-4 Inverter shows ITE error?
If your INVT Inverter displays 'ITE', it could be due to loose wires or connectors on the control board (check the connector and rewire), a damaged assistant circuit (ask for support), a damaged Hall sensor (ask for support), or an abnormal amplifying circuit (ask for support).
Why does my INVT CHV180-004G-4 trip the input switch when running?
If your INVT Inverter displays 'The inverter displays normally when power on, but switch at the input side trips when running', inspect whether the output side of inverter is short circuit. If yes, ask for support. Inspect whether ground fault exists. If yes, solve it. If trip happens occasionally and the distance between motor and inverter is too far. It is recommended to install output AC reactor.
What should I do if my INVT CHV180-004G-4 Inverter is running but the motor won’t move?
If your INVT Inverter displays 'Motor doesn’t move after inverter running', inspect if there is balanced three-phase output among U, V, and W. If yes, then motor could be damaged, or mechanically locked. Please solve it. If the output is unbalanced or lost, the inverter drive board or the output module may be damaged. ask for support.
Details the layout and function of main circuit and control terminals.
Provides a comprehensive wiring diagram for system setup.
Covers connections for power supply, motor, and braking units.
Provides guidelines for proper installation to ensure electromagnetic compatibility.
Explains the functions of the inverter's keypad buttons and indicators.
Details procedures for parameter setting, fault reset, and autotuning.
Configures fundamental inverter settings like speed control mode and run command source.
Adjusts acceleration, deceleration, and multi-step speed settings for smooth operation.
Sets motor-specific parameters for optimal performance and autotuning.
Optimizes vector control performance with PI loop and filter settings.
Configures various protection features like phase-failure and overload protection.
Provides a table of fault codes, types, reasons, and solutions for diagnosing issues.
Discusses common operational faults like no display, motor not moving, and tripping.
Guides on setting parameters, debugging, autotuning, and S-curve adjustment.
Configures fundamental inverter settings like speed control mode.
Adjusts acceleration, deceleration, and multi-step speed settings.
Sets motor-specific parameters for optimal performance and autotuning.
Optimizes vector control performance with PI loop and filter settings.
Configures various protection features like phase-failure and overload protection.