CHV180 series frequency inverter special for elevator Appendix D
.150.
Function
Code
Name Description
Factory
Setting
Mod
ify
LCD Display
P9.07
Threshold of over
speed deviation
0.0%~50% 0.0~50
20.0
%
P9.08 Reserved 0.000~10.000s
0.000~10.0
00
0.50
00
RESERVE
PA Group: Serial communication
PA.00
Local address
1~247
0: broadcast address
1
LOCAL
ADDRESS
PA.01
Communication baud
rate selection
0: 1200BPS
1: 2400BPS
2: 4800BPS
3: 9600BPS
4: 19200BPS
5: 38400BPS
4
BAUD RATE
PA.02
Data format
0: No p
arity (8,N,2) for
RTU
1: Even parity (8,E,1)
for RTU
2: Odd parity (8,O,1)
for RTU
3: No parity (8,N,2) for
ASCII
4: Even parity (8,E,1)
for ASCII
5: Odd parity (8,O,1)
for ASCII
6: No parity (7,N,2) for
ASCII
7: Even parity (7,E,1)
for ASCII
8: Odd parity (7,O,1)
for ASCII
1
DATA
FORMAT
PA.03
Communication
response delay time
0~20ms 0
COM DELAY
TIME