CHV180 series frequency inverter special for elevator Appendix D
.132.
Function
Code
Name Description
Factory
Setting
Mod
ify
LCD Display
speed SPEED
P0.06
Running direction
selection
0: Forward
1: Reverse
2: Forbid reverse
0
RUN
DIRECTION
P0.07 Carrier frequency 1.0~16.0kHz
Depend on
model
CARRIER
FREQ
P0.08
Motor parameters
autotuning
0: No action
1: Rotation autotuning
2: Static autotuning
0
AUTOTUNIN
G
P0.09 Restore parameters
0: No action
1: Restore factory
setting
2: Clear fault records
3:Restore parameters
for injection molding
machine
0
RESTORE
PARA
P0.10
~P0.11
Reserved 0~65536 0
RESERVE
P1 Group: Speed curve
P1.00 Multi-step speed 0
0.000~P0.02 0.000m/s
MULTI-
STEP
SPEED 0
P1.01 Multi-step speed 1
0.000~P0.02 0.000m/s
MULTI-STEP
SPEED 1
P1.02 Multi-step speed 2
0.000~P0.02 0.000m/s
MULTI-STEP
SPEED 2
P1.03 Multi-step speed 3
0.000~P0.02 0.000m/s
MULTI-STEP
SPEED 3
P1.04 Multi-step speed 4
0.000~P0.02 0.000m/s
MULTI-STEP
SPEED 4
P1.05 Multi-step speed 5
0.000~P0.02 0.000m/s
MULTI-STE
P
SPEED 5
P1.06 Multi-step speed 6
0.000~P0.02 0.000m/s
MULTI-
STEP