CHV180 series frequency inverter special for elevator Appendix D
.140.
Function
Code
Name Description
Factory
Setting
Mod
ify
LCD Display
P6.01 Y1 output selection
0: NO output
1: Elevator running
2: Up running
3: Down running
4: Fault output
5: Zero speed running
6: Ready
7: Brake control
8: Contactor control
9: Frequency reached
10: FDT reached
11: Elevator running
12: Holding-brake
output
13~20: Reserved
1
Y1
SELECTION
P6.02 Y2 output selection
0
Y2
SELECTION
P6.03
HDO open collector
output selection
0
HDO
SELECTION
P6.04
Relay 1 output
selection
4
RO1
SELECTION
P6.05
Relay 2 output
selection
5
RO2
SELECTION
P6.06
Relay 3 output
selection
0
RO3
SELECTION
P6.07
AO1 function
selection
1:Running speed
2:Reference speed
3:Motor running speed
4:Output current
5:Output voltage
6:Output power
7:Output torque
8:AI1 input
9:AI2 input
10~14:Reserved
0
AO1
SELECTION
P6.08
AO2 function
selection
1
AO2
SELECTION
P6.09
HDO open collector
high speed pulse
output selection
0
HDO
SELECTION
P6.10 AO1 lower limit 0.0%~P6.12 0.0%
AO1 LOW
LIMIT
P6.11
AO1 lower limit
corresponding output
0.00V ~10.00V 0.00V
AO1 LOW
OUTPUT
P6.12 AO1 upper limit P6.10~100.0% 100.0%
AO1 UP LIMIT
P6.13
AO1 upper limit
corresponding output
0.00V ~10.00V 10.00V
AO1 UP
OUTPUT
P6.14 AO2 lower limit 0.0%~P6.16 0.0%
AO2 LOW