Starting frequency of DC braking: start the DC 
braking when running frequency reaches starting 
frequency determined by P01.09. 
Waiting time before DC braking: VFDs blocks the 
output before starting the DC braking. After this 
waiting time, the DC braking will be started so as 
to prevent over-current fault caused by DC 
braking at high speed. 
DC braking current: the value of P01.11 is the 
percentage of rated current of VFD. The bigger 
the DC braking current is, the greater the braking 
torque is.   
DC braking time: the retention time of DC 
braking. If the time is 0, the DC braking is invalid, 
and the VFD will coast to stop. 
 
Setting range of P01.09: 0.00Hz –P00.03 
(the max. frequency) 
Setting range of P01.10: 0.00 – 50.00s 
Setting range of P01.11: 0.0 – 100.0% 
Setting range of P01.12: 0.00 – 50.00s 
During the procedure of switching FWD/REV 
rotation, set the threshold by P01.14, which is as 
the table below.