Goodrive200 inverters                                                                                    Function codes   
125 
Function 
code 
Name 
Detailed instruction of parameters 
Default 
value
P13.13 
Braking 
current of 
short-circui
t   
When P01.00=0 during the starting of the 
inverter, set P13.14 to a non-zero value to enter 
the short circuit braking.   
When the running frequency is lower than P01.09 
during the stopping of the inverter, set 13.15 to a 
non-zero value to enter into stopping short 
circuited braking and then carry out the DC 
braking at the time set by P01.12 (refer to the 
instruction of P01.09~P01.12) . 
Setting range of P13.13: 0.0~150.0% 
(the inverter) 
Setting range of P13.14: 0.00~50.00s 
Setting range of P13.15: 0.00~50.00s 
0.0%  ○ 
P13.14 
Braking 
retention 
0.00s  ○ 
P13.15 
The 
braking 
retention 
0.00s  ○ 
P14 Group    Serial communication   
P14.00
Local 
communic
ation 
address 
The setting range:1~247   
When the master is writing the frame, the 
communication address of the slave is set to 0; 
the broadcast address is the communication 
address. All slaves on the MODBUS fieldbus can 
receive the frame, but the salve doesn’t answer.
The communication address of the drive is 
unique in the communication net. This is the 
fundamental for the point to point communication 
between the upper monitor and the drive.   
Note: The address of the slave cannot set to 0. 
Communic Set the digital transmission speed between the  4  ○