Physical accident may occur if the motor starts up suddenly during
autotune. Please check the safety of surrounding environment of the
motor and the load before autotune.
The power is still applied even the motor stops running during static
autotune. Please do not touch the motor until the autotune is
completed, otherwise there would be electric shock.
Do not carry out the rotation autotune if the motor is coupled with the
load, please do not operate on the rotation autotune. Otherwise
misaction or damage may occur to the inverter or the mechanical
devices. When carry out autotune on the motor which is coupled with
load, the motor parameter won’t be counted correctly and misaction
may occur. It is proper to de-couple the motor from the load during
autotune when necessary.
Ready
P00.01=0
P02.01~P02.05
P00.15=1 P00.15=3
P00.15
Press “RUN” to begin
autotuning
Display“-END-”
Autotuning
End
P00.15=2
The control performance of the inverter is based on the established accurate motor model. The
user has to carry out the motor autotune before first running (take motor 1 as the example).