Function    Instructions   
come back to the value after the frequency increasing 
or decreasing.   
34  DC braking   
The inverter will begin DC braking after the valid 
command.   
35  Reserved     
36 
Shift the command to the 
keypad 
After the function terminal become valid, the running 
command channel will be shifted into keypad running 
command channel and the running command channel 
will come back to the original state if the function 
terminal is invalid.   
37 
Shift the command to the 
terminals 
After the function terminal become valid, the running 
command channel will be shifted into terminal running 
command channel and the running command channel 
will come back to the original state if the function 
terminal is invalid. 
38 
Shift the command to the 
communication 
After the function terminal become valid, the running 
command channel will be shifted into communication 
running command channel and the running command 
channel will come back to the original state if the 
function terminal is invalid. 
39  Pre-exciting command    The function is started if the command is valid   
40  Power consumption clear 
The power consumption will be cleared after the 
command is valid.   
41  Power consumption retention