Goodrive300 Series VFD Function parameters
79
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
output
26: Voltage establishment finished
2730: Reserved
P06.05
Polarity of
output
terminals
The function code is used to set the pole of the
output terminal.
When the current bit is set to 0, the input terminal
is anode.
When the current bit is set to 1, the input terminal
is cathode.
BIT0
BIT1
BIT2
BIT3
Y1
HDO
RO1
RO2
Setting range: 000F
00
P06.06
Y1 switch-on
delay time
The function code defines the corresponding
delay time of the electrical level change during
the programmable terminal switching on and off.
Y electrical level
Y valid
Invalid
Switch-on
delay
Invalid
Valid
Switch-off
delay
Setting range: 0.00050.000s
Note: P06.08 and P06.08 are valid only when
P06.00=1.
0.000s
P06.07
Y1 switch-off
delay time
0.000s
P06.08
HDO
switch-on
delay time
0.000s
P06.09
HDO
switch-off
delay time
0.000s
P06.10
RO1 switch-on
delay time
0.000s
P06.11
RO1 switch-off
delay time
0.000s
P06.12
RO2 switch-on
delay time
0.000s
P06.13
RO2 switch-off
delay time
0.000s
P06.14
AO1 output
0: Running frequency
1: Set frequency
2: Ramp reference frequency
3: Running rotation speed (relative to 2 times the
synchronous rotation speed of the motor)
4: Output current (relative to 2 times the rated
current of the VFD)
0
P06.15
AO2 output
0
P06.16
HDO
high-speed
pulse output
0