Goodrive350 series high-performance multi-function inverter  Chapter 6 
-137- 
Detailed parameter description 
coefficient of 
constant-power 
zone 
T
f
0.1
Flux-weakening 
coefficient of motor
1.0
2.0
Min. flux-weakening limit of motor
 
P03.22 and P03.23 are valid during constant power. 
When  motor  speed  is  above  rated  speed,  motor 
enters  flux-weakening  running  state.  The 
flux-weakening  control  coefficient  can  change  the 
flux-weakening curvature, the larger the coefficient, 
the steeper the curve, the smaller the coefficient, the 
smoother the curve.   
Setting range of P03.22: 0.1–2.0 
Setting range of P03.23: 10%–100% 
Min. 
flux-weakening 
point of 
constant-power 
zone 
P03.24 sets the max. output voltage of the inverter, 
which is the percentage of rated motor voltage. This 
value should be set according to field conditions. 
Setting range:0.0–120.0% 
Carry out motor pre-exciting during starting to build a 
magnetic field inside the motor to improve the torque 
characteristics of motor during starting. 
Setting range: 0.000–10.000s 
Flux-weakening 
proportional gain 
Vector control 
speed display 
0: Display as per actual value 
1: Display as per the set value 
Static friction 
compensation 
coefficient 
Corresponding 
frequency point 
of static friction 
High speed 
friction 
compensation