Goodrive350 series high-performance multi-function inverter Chapter 6
-196-
Function
code
Name
Detailed parameter description
Default
value
Modi
fy
P19.05
Software version
of the extension
card in card slot 3
0.00655.35
0.00
P19.06
Input state of
extension I/O
card terminals
00xFFFF
0
P19.07
Output state of
extension I/O
card terminals
00xFFFF
0
P19.08
HDI3 input
frequency of
extension I/O
card
0.00050.000kHz
0.000
kHz
P19.09
AI3 input voltage
of extension I/O
card
0.0010.00V
0.00V
P19.10
P19.39
Reserved
variables
065535
0
P20 group Encoder of motor 1
P20.00
Encoder type
display
0: Incremental encoder
1: Resolver-type encoder
2: Sin/Cos encoder
3: Endat absolute encoder
0
P20.01
Encoder pulse
number
Number of pulses generated when the encoder
revolves for one circle.
Setting range: 060000
1024
P20.02
Encoder direction
Ones: AB direction
0: Forward
1: Reverse
Tens: Z pulse direction (reserved)
0: Forward
1: Reverse
Hundreds: CD/UVW pole signal direction
0: Forward
1: Reverse
0x000
P20.03
Detection time of
encoder offline
fault
The detection time of encoder offline fault.
Setting range: 0.010.0s
1.0s
P20.04
Detection time of
Detection time of encoder reversal fault.
0.8s