Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-62-
Detailed instruction of parameters
Note: Setting modes 2~7, 100% corresponds to
three times of the rated current of the motor.
Setting range: -300.0%~300.0% (rated current of the
motor)
Torque
reference
filter time
Upper
frequency of
forward
rotation in
torque
control
0: Keypad (P03.16 sets P03.14, P03.17 sets P03.15)
1: AI1
2: AI2
3: AI3
4: Pulse frequency HDI setting upper-limit frequency
5: Multi-step setting upper-limit frequency
6: Modbus communication setting upper-limit
frequency
7~9: Reserved
Note: Setting modes 1~6, 100% corresponds to
the maximum frequency.
Upper
frequency of
reverse
rotation in
torque
control
Keypad
setting for
upper
frequency of
forward
rotation
This function is used to set the upper limit of the
frequency. P03.16 sets the value of P03.14; P03.17
sets the value of P03.15.
Setting range: 0.00 Hz~P00.03 (the Max. output
frequency)
Keypad
setting for
upper
frequency of
reverse
rotation