Goodrive300-19 series open loop vector inverter special for hosit Function parameters
-61-
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
The setting range of P03.05: P03.02~P00.03 (the
Max. output frequency)
P03.06
Speed loop
output filter
0~8 (corresponding to 0~2
8
/10ms)
0
P03.07
Compensation
coefficient of
electromotion
slip
Slip compensation coefficient is used to adjust the
slip frequency of the vector control and improve the
speed control accuracy of the system. Adjusting the
parameter properly can control the speed static error.
Setting range: 50%~200%
100%
P03.08
Compensation
coefficient of
braking slip
100%
P03.09
Current loop
percentage
coefficient P
Note:
1.These two parameters adjust the PI adjustment
parameter of the current loop which affects the
dynamic response speed and control accuracy
directly. Generally, users do not need to change
the default value.
2.Only apply to the vector control mode without
PG 0 (P00.00=0).
Setting range: 0~65535
1000
P03.10
Current loop
integral
coefficient I
1000
P03.11
Torque
setting
method
This parameter is used to enable the torque control
mode, and set the torque.
0: Torque control is invalid
1: Keypad setting torque (P03.11)
2: Analog AI1 setting torque
3: Analog AI2 setting torque
4: Analog AI3 setting torque
5: Pulse frequency HDI setting torque
6: Multi-step torque setting
7: Modbus communication setting torque
8: Reserved
9: Reserved
10: Reserved
0

Table of Contents