EasyManua.ls Logo

INVT Goodrive GD35-004G-4-H1

INVT Goodrive GD35-004G-4-H1
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Goodrive35 Series Closed-loop Vector Control VFD Function parameters
101
Functio
n code
Name
Detailed instruction of parameters
Default
value
Modif
y
step 4
P10.02
P10.04
P10.06
P10.32
P10.30
P10.28
Deceleration time
(two sections)
Acceleration time
(two sections)
P10.03 P10.05 P10.07 P10.31 P10.33
If multi-step speed operation is selected, multi-step
speeds are in the range of --f
max
f
max
and it can be
set continuously. The start/stop of multi-step running
is also determined by P00.01.
Goodrive35 series VFDs can set 16 stages speed,
selected by the combination of multi-step terminals
14 (select the setting by S terminals, the
corresponding function codes are P05.01P05.09),
corresponding to the speed 1 to speed 15.
Output frequency
t
t
t
t
t
Terminal 1
Terminal 2
Terminal 3
Terminal 4
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
ON ON
ON
ON ON
ON ON ON
ON
ON
ON
ON
ON
ON
ON
When terminal 1, 2, 3, 4=OFF, the frequency input
mode is selected via P00.06 or P00.07. When
terminal 1, 2, 3, and 4 are not off, they run at
multi-step which takes precedence of keypad,
analog value, high-speed pulse, PLC, and
communication frequency input.
The relation between terminal 1, 2, 3, 4 and
multi-step speed is as following:
Terminal 1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Terminal 2
OFF
OFF
ON
ON
OFF
OFF
ON
ON
Terminal 3
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Terminal 4
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Step
0
1
2
3
4
5
6
7
Terminal 1
OFF
ON
OFF
ON
OFF
ON
OFF
ON
P10.12
Multi-step speed 5
0.0%
P10.13
The running time of
step 5
0.0 s
P10.14
Multi-step speed 6
0.0%
P10.15
The running time of
step 6
0.0 s
P10.16
Multi-step speed 7
0.0%
P10.17
The running time of
step 7
0.0 s
P10.18
Multi-step speed 8
0.0%
P10.19
The running time of
step 8
0.0 s
P10.20
Multi-step speed 9
0.0%
P10.21
The running time of
step 9
0.0 s
P10.22
Multi-step speed 10
0.0%
P10.23
The running time of
step 10
0.0 s
P10.24
Multi-step speed 11
0.0%
P10.25
The running time of
step 11
0.0 s
P10.26
Multi-step speed 12
0.0%
P10.27
The running time of
step 12
0.0 s
P10.28
Multi-step speed 13
0.0%
P10.29
Running time of step
13
0.0 s
P10.30
Multi-step speed 14
0.0%
P10.31
Running time of step
14
0.0 s
P10.32
Multi-step speed 15
0.0%
P10.33
Running time of step
15
0.0 s

Table of Contents