Goodrive35 Series Closed-loop Vector Control VFD Function parameters
108
Functio
n code
Name
Detailed instruction of parameters
Default
value
Modif
y
motor and the standard
one is huge, the
features of the VFD will
decrease.
Note: Reset the rated
power of the motor
(P12.01), and initialize
the motor parameter of
P12.02P12.05.
P12.06
Stator resistor of AM
2
0.00165.535 Ω
After finish the motor
parameter autotuning,
the set value of
P12.06P12.10 will
renew automatically.
These parameters are
basic parameters
controlled by vectors
which directly impact
the features.
Note: Users cannot
modify the parameters
freely.
Depend
on model
P12.07
Rotor resistor of AM
2
0.00165.535 Ω
Depend
on model
P12.08
Leakage inductance
of AM 2
0.16553.5 mH
Depend
on model
P12.09
Mutual inductance of
AM 2
0.16553.5 mH
Depend
on model
P12.10
Non-load current of
AM 2
0.16553.5 A
Depend
on model
P12.11
Magnetic saturation
coefficient 1 for iron
core of AM2
0.0100.0%
85.0%
P12.12
Magnetic saturation
coefficient 2 for iron
core of AM2
0.0100.0%
75.0%
P12.13
Magnetic saturation
coefficient 3 for iron
core of AM2
0.0100.0%
68.0%
P12.14
Magnetic saturation
coefficient 4 for iron
core of AM2
0.0100.0%
40.0%
P12.15
Rated power of SM 2
0.13000.0 kW
Set the parameter of the
controlled AM.
In order to ensure the
controlling performance,
Depend
on model
P12.16
Rated frequency of
SM 2
0.01 HzP00.03 (max.
output frequency)
50.00
Hz