Goodrive35 Series Closed-loop Vector Control VFD  Function parameters 
126 
Detailed instruction of parameters 
0: Unbiased 
1: Biased 
Bit1:Servo enabled 
0: Disabled (Terminal enabled) 
1: Enabled 
  Under  the  pulse  string  positioning  mode  or  the 
spindle  positioning  mode,  Servo  enable  signal  is 
valid, the VFD will run into the servo mode, if there is 
no  servo  enable  signal,  the  VFD  needs  to  receive 
the forward or reverse run command to perform the 
servo operation mode. 
Bit2:Speed exchange position mode 
0: First stop and the switch 
1: Direct switching 
Setting range: 0x0000–0x3133 
Pulse command in pulse position mode 
Ones: pulse mode 
0: A/B quadrature pulse, A is forward to B 
1: A: PULSE; B: SIGN 
2: A: Positive PULSE 
3: A: Negative PULSE 
Tens: Pulse direction   
Bit0: Direction setting   
0: Forward 
1: Reverse 
Bit1:  Pulse  direction  determined  by  the  operation 
direction 
0: Disabled 
1: Enabled 
Hundreds: Pulse and direction selection 
0: No frequency multiplication 
1: Frequency multiplication 
Thousands: Pulse control 
Bit0: Pulse filtering selection   
0: Inertial filter 
1: Moving average filtering 
Bit1: Overspeed suppression 
0: No suppression 
1: Suppression