Goodrive20-EU series VFD Function parameters
72
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
P07.27
Type of
present fault
0: No fault
1: OUt1
2: OUt2
3: OUt3
4: OC1
5: OC2
6: OC3
7: OV1
8: OV2
9: OV3
10: UV
11: Motor overload (OL1)
12: VFD overload (OL2)
13: Input side phase loss (SPI)
14: Output side phase loss (SPO)
15: Overheat of rectifier module (OH1)
16: Overheat fault of VFD module (OH2)
17: External fault (EF)
18: 485 communication fault (CE)
19: Current detection fault (ItE)
20: Motor autotune fault (tE)
21: EEPROM operation fault (EEP)
22: PID feedback offline fault (PIDE)
23: Brake unit fault (bCE)
24: Running time reached (END)
25: Electronic overload (OL3)
26: Panel communication error (PCE)
27: Parameter upload error (UPE)
28: Parameter download error (DNE)
29 31: Reserved
32: To-earth short circuit fault 1 (ETH1)
33: To-earth short circuit fault 2 (ETH2)
34: Speed deviation fault (dEu)
35: Maladjustment (STo)
36: Underload fault (LL)
37: Safe torque off (STO)
38: Channel 1 is abnormal (STL1)
39: Channel 2 is abnormal (STL2)
P07.28
Type of the last
fault
P07.29
Type of the last
but one fault
P07.30
Type of the last
but two fault
P07.31
Type of the last
but three fault
P07.32
Type of the last
but four fault

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the INVT Goodrive20-EU VFD Series and is the answer not in the manual?

INVT Goodrive20-EU VFD Series Specifications

General IconGeneral
BrandINVT
ModelGoodrive20-EU VFD Series
CategoryDC Drives
LanguageEnglish

Related product manuals