Goodrive300-01A series VFD for air compressor Function code description
-29-
6: Set via multi-step speed running
7: Set via PID control
8: Set via Modbus communication
9–11: Reserved
Reference object of B
frequency command
0: Max. output frequency
1: A frequency command
Combination mode of
setting source
0: A
1: B
2: (A+B)
3: (A-B)
4: Max. (A, B)
5: Min. (A, B)
Frequency set through
keypad
0.00 Hz–P00.03 (max. frequency)
0: Run by default direction
1: Run by reverse direction
2: Reverse running prohibited
Carrier frequency
setting
Motor parameter
autotuning
0: No operation
1: Rotary autotuning
2: Static autotuning 1 (comprehensive
autotuning)
3: Static autotuning 2 (partial autotuning)
0: Invalid
1: Valid during the whole time
Function parameter
restoration
0: No operation
1: Restore to default value
2: Clear fault history
Note: When restoring to default values, the
motor parameters in P02 group will stay in
current value; in addition, P18.04, P18.28,
P18.29, P18.32, P18.33, P18.38 in P18 group