iMars grid-tied solar inverters Display panel
48
Setting item
LCD display
Instruction
Set power
set power
P-Lmt
Mode
LmtPower
P.Factor
Limit Mode Invalid
Invalid
Auto
Manual
Limit Power
100%
Power Factor
Grid Tied Mode
Normal Mode
Power Factor 1.00
Input password
0000
The password is needed when enter into
the interface of “Set power”. Get
the
password from the supplier if necessary.
There are 3 submenus:
ķP-
Lmt Mode:
invalid (limited power function is
invalid),auto (special for single
phase) ,manual (set the limit of output
value manually);
ĸ LmtPower: this
function is only valid when the
P-Lmt
Mode is manual, the percentage is that
of the rated power and the setting range
is from 10% to 100%;
Ĺp.Factor:
includes normal model (default value
“1”), current advanced mode and current
hysteresis mode and the setting rage is
-0.9
-0.99.
(the machine of three phase only has the
function of
Ĺ)