Below is an example for configuration 3, with D
1
=0.9 m and D
2
= 1.6 m.
5.4.5 Calculate the real detection distance
The actual detection distance Dalarm is the value to be entered on the Configuration page of the Inxpect Safety
application.
Dalarm indicates the maximum distance between the sensor and the object to be detected.
5.5 Sensor position recommendations
5.5.1 For access detection function
Below are some recommendations for the sensor positioning for the access detection function:
l if the distance between the ground and the bottom portion of the field of view is greater than 30 cm (11.8
in), take precautions area to make sure that even a person entering the dangerous area by crawling on the
floor is still detected.
l if the height above the ground is less than 30 cm (11.8 in), install the sensor with an inclination of minimum
10° upwards.
5.5.2 For access control of an entrance
Below are some recommendations for the sensor positioning if it is installed for controlling an entrance:
l height above the ground: 30 cm (11.8 in)
l angular coverage: 90°
l inclination: 40° upwards
l rotation around z-axis: 90°
5. Sensor position
SBV System Series| Instruction manual v1.2 DEC 2021|SAF-UM-SBVBus-en-v1.2|© 2021 Inxpect SpA
47

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Inxpect SBV System Series and is the answer not in the manual?

Inxpect SBV System Series Specifications

General IconGeneral
BrandInxpect
ModelSBV System Series
CategoryRadar
LanguageEnglish