Offsets Section. When the correct offsets are made, touch SAVE. If the system is non-zoned, the
indoor temperature offset is found on this screen. If the system is zoned, the indoor temperature
offset is found in the Zoning, Offsets screen.
Outdoor temperature: Adjustable from -5 to 5°F (-3 to 3°C). Default = 0°F
Indoor temperature: Adjustable from -5 to 5°F (-3 to 3°C). Default = 0°F
Humidity: Adjustable from -10 – 10%. Default = 0%
NOTE: For single-zone systems, the indoor temperature offset is on this screen. For zoning
systems, there is a separate zone indoor temperature offset screen in the zoning menu.
A190275
6.3.1.4. Reset Factory Defaults
This option allows the installer to reset certain factory parameters. After the selections are
made, touch SAVE.
Program Schedule: Reset back to pre-programmed time and temperature.
User Settings: Reset user settings back to pre-programmed values.
Install Settings: Reset installation settings back to pre-programmed values.
Last 10 Events: Reset the last 10 system events under the Service menu.
A190397
6.3.1.5. Scheduling On/Off
This option lets the installer allow comfort schedule programming features. After the selection
is made, touch SAVE.
Scheduling: On or Off. Default = On