TABLE OF ALARM AND ERROR CODES:
Alarm message Event Actions to take
C22 Brush protection short
circuit: inhibits all
functions.
Resettable only by pressing the
OFF button of the machine.
C14 Heatsink
overtemperature:
activated if the
temperature exceeds
90°C (194°F).
Error condition resets
automatically when the
temperature drops below 90°C
(176°F).
FS0 Worn brushes. Replace brushes.
SP1 Brush fault Error resettable only by switching
o󰀨 the machine. Trips if the
brushes cut out three times within
the space of one minute.
Yellow Led alight Battery reserve charge. Error condition that does not
inhibit any function: the condition
is indicated by the yellow Led
lighting up.
Red Led blinking Reserve charge
depleted.
Error condition inhibiting all
functions: resettable only by
pressing the OFF button on the
machine.
P1.X Value of “work program
1” parameter.
See programming.
P2.X Value of “work program
2” parameter.
See programming.
SF.X Value of "lter shaker
function" parameter.
See programming.
X = VALUE RANGING BETWEEN “0” AND “9”
PROGRAMMING:
If the display shows P1.0, P2.1, and SF.3, simply switch o󰀨 the machine. (these settings are
programmed by the manufacturer).
If the display shows a value higher than those indicated above (e.g. P1."5", P2."7", SF."9")
continue to follow the instructions given below.
To restore the default factory settings for the machine, set the power switch to ON, then press
the programming button on the control panel (battery/hourglass symbols) and hold for at least 3
seconds.
P1.X will appear in the display. Value “P1” should be “0” (P1.0); if the value displayed is higher
than “0”, press the “activate suction fan” button to return the value in the display to “P1.0”. Press
the programming button (battery/hourglass symbols) to move to the next parameter.
Value “P2” should be “1” (P2.1); if a di󰀨erent value is displayed, press the “activate suction fan”
button to set the correct value. Press the programming button (battery/hourglass symbols) to pass
on to the nal parameter.
Value “SF.X” should be SF.3; if a di󰀨erent value is displayed, press the “lter shaker” button to set
the correct value.
To exit programming mode, switch o󰀨 the machine.