GB
► Emergency bypass (1, g. 11): Use this lever to
move the machine with the engine off. Press in the
direction shown to disengage the hydraulic pump.
► Bin tipping lever (top unloading) (g. 7): Pull this
lever to rotate the bin and empty its contents.
► Emergency stop button (1, g. 12): Press this
mushroom head button in the event of imminent dan-
ger or need to deactivate all machine functions and
disconnect power to the machine.
► Choke (1, g. 13): Pull to engage the choke for cold
starting.
► Filter shaker button (2, g. 13): Shut off suction with
the suction control lever and then press and hold this
button for 30 seconds to shake and clean the suction
lter.
► Bin up/down switch (3, g. 13): Lifts or lowers the
debris bin.
► Horn button (4, g. 13): Press to sound the horn.
► Main switch (5, g. 13): Switches power to all machine
functions on/off.
► Voltage indicator (6, g. 13): Shows correct electric
circuit voltage.
► Hour counter (7, g. 13): Shows machine operating
hours.
► Engine speed control lever (8, g. 13): Move this le-
ver to adjust engine speed.
O
F
F
O
N
S
T
A
R
T
2 3 4 5
6 7 8
9 10
1
13
12
11
7
23