Operating the Petrol and Diesel versions
Sit correctly in the seat.
Release the parking brake.
Move the engine speed control lever to START position.
Pull out the choke.
Move the engine drive lever to position 1-START and hold it there while turning the ignition
key to START position.
! WARNING!
Do not engage the starter motor for more than ve seconds at a time. If the engine fails to
start, release the ignition key and wait ten seconds before trying again.
Allow the ignition key to return to ON position as soon as the engine starts and release the
engine drive lever.
Press on the direction selector pedal to move off. Press the right side to move forwards.
Press the left side to move backwards.
Lower the side brushes.
Lower the main brush.
Adjust the suction control lever to obtain the required strength of suction.
Press the ap lift pedal only when you need to pick up large but light objects.
Cleaning quality depends largely on the cleanliness of the suction lter. Operate the lter
shaker at intervals suitable to the environment in which you are using the machine.
Emptying the bottom unloading debris bin
! WARNING!
When emptying the bin, always wear a mask to protect the respiratory tract from the dust
which is always present during this operation.
! WARNING!
Before emptying the debris bin, operate the lter shaker for 30 seconds to clean the lter
Release the bin lock (g. 14).
Pull out the rear bin by means of its handle.
Take the bin (which is tted with wheels) to the rubbish collection point and empty it.
14