Questions and Answers

  • J
    Jordan SmithAug 19, 2025
    What to do if IPG Photonics Measuring Instruments show High Back Reflection error?
    • D
      Darlene BarrAug 19, 2025
      If the Measuring Instruments by IPG Photonics display a 'High Back Reflection' error, it means the back reflected power has exceeded the pre-installed maximal applicable level. First, check that the focus position is correctly adjusted and that there are no surfaces that could cause high back reflection. Then, reset the error using the RS-232 command (“RERR”) or the touch-screen display on the front panel.
  • M
    Michele WoodAug 21, 2025
    Why do IPG Photonics Measuring Instruments show Overheat error?
    • T
      tracey36Aug 21, 2025
      If you see a 'Overheat' error on your IPG Photonics Measuring Instruments, it indicates that the case temperature of the laser is too high. Check if the outside conditions are within the specified range and ensure sufficient airflow. The error message should disappear once the case temperature drops back within the operating range.
  • C
    Cheryl AndersonAug 25, 2025
    What to do if IPG Photonics Measuring Instruments show Power Supply Failure 2 error?
    • G
      Gloria HessAug 25, 2025
      If your IPG Photonics Measuring Instruments display a 'Power Supply Failure 2' error, it means that while the internal main power supply is on and voltage is applied to the laser module, the voltage value is outside the expected range. Try resetting the error and ensure the internal main power supply is switched on. If the error continues, contact IPG Photonics for assistance.
  • W
    waynerobertsAug 26, 2025
    What to do if IPG Photonics Measuring Instruments show Power Supply Failure error?
    • K
      Kevin AvilaAug 26, 2025
      If your IPG Photonics Measuring Instruments displays a 'Power Supply Failure' error, it indicates that, despite the internal main power supply being switched on, no voltage is being applied to the laser module. Try resetting the error. If the error persists, contact IPG Photonics for assistance.
  • T
    Tina AdamsAug 27, 2025
    What to do if IPG Photonics Measuring Instruments show Module Disconnected error?
    • T
      Taylor JonesAug 28, 2025
      If your IPG Photonics Measuring Instruments show a 'Module Disconnected' error, it means that digital data communication with the laser module inside the device is broken. Try resetting the error. If the error appears again, contact IPG Photonics for assistance.
  • J
    Jordan ParkAug 30, 2025
    What to do if IPG Photonics Measuring Instruments show Duty Cycle Too High error?
    • A
      Anthony AcostaAug 30, 2025
      If your IPG Photonics Measuring Instruments shows 'Duty Cycle Too High' error, the duty cycle is the percentage of how long the laser is in the “on” state in the given modulated period. Check the modulation signal and try to reset the error. If it appears again, contact IPG Photonics for assistance.
  • V
    victor58Sep 1, 2025
    What to do if IPG Photonics Measuring Instruments show Internal Communication Error?
    • R
      Rebecca ClineSep 1, 2025
      If your IPG Photonics Measuring Instruments display a 'Internal Communication Error', it occurs when there is no connection to the Controller Area Network (CAN). Try to reset the error. If it appears again, contact IPG Photonics for assistance.
  • K
    Kenneth WestSep 3, 2025
    What to do if IPG Photonics Measuring Instruments show High Pulse Energy error?
    • C
      Christina GonzalezSep 3, 2025
      If your IPG Photonics Measuring Instruments show a 'High Pulse Energy' error, check the modulation signal. Try to reset the error. If it appears again, contact IPG Photonics for assistance.
  • M
    Michelle YoderSep 5, 2025
    What to do if IPG Photonics Measuring Instruments show Pulse Too Long error?
    • J
      Justin JonesSep 5, 2025
      If your IPG Photonics Measuring Instruments display a 'Pulse Too Long' error, check the modulation signal. Try to reset the error. If it appears again, contact IPG Photonics for assistance.
  • S
    Stephanie GilesSep 7, 2025
    What to do if IPG Photonics Measuring Instruments show Average Power Too High error?
    • C
      Charles NguyenSep 7, 2025
      If your IPG Photonics Measuring Instruments display a 'Average Power Too High' error, check the modulation signal. Try to reset the error. If it appears again, contact IPG Photonics for assistance.

Summary

1 Overview of the YLR-Series Fiber Lasers

Safety Information and Conventions

Explains safety symbols and conventions used in the guide.

General Safety Instructions

Outlines essential safety precautions for operating the laser.

2 Using Your Device

Front Panel View

Describes the components and functions of the laser's front panel.

Rear Panel View

Describes the components and functions of the laser's rear panel.

Operation Control Modes

Explains how to select between local and remote control modes.

3 Computer Interface;Commands

4 Pulse Shaping

Using the Pulse Shaper Program

Explains the interface and basic operations of the pulse shaping software.

5 Troubleshooting

Error Messages on the Display and Status Bits

Lists error messages and their corresponding solutions.

A Web User Utility

B Service

C Optical Fiber Connector Inspection and Cleaning

D Warranty

E Product Returns