M820 pH/Dual ORP Controller Owner’s Manual
a. Set Level
1. Default: 640 mV
2. Selectable range: 400 mV to 890 mV (in 5 mV
increments), cannot be set for less than 10 mV below
the ORP1 set level.
b. Dose Time
1. Default: OFF. In the med dose cycle mode, the dose
LED will ash while dosing and illuminate steadily during
the delay poron of the med cycle. In connuous dose
mode, the dose LED will ash while dosing, and dosing
will connue unl ORP is 10 mV above Set Level.
2. Selectable range: OFF, CON (connuous), and Timed
(10 to 900 seconds ON)
c. Delay Time
1. Default: OFF. Delay me of 5 minutes between feed
cycles (med feed only). Aer dose me, the controller
will wait (delay) for the specied minutes before
checking the current level and dosing again if necessary.
2. Selectable range: 1 - 99 minutes.
d. Over Timer
1. Default: ON. The Over Timer does not automacally
reset. It must be reset by using the mode buon to
cycle out of auto and then back to auto mode.
2. The Over Timer is interlocked with the Dose Time
selecon.
3. If the Dose Time is set to a med cycle, the Over Timer
will count med feed cycles. Every me the set level is
reached the Over Timer will reset the count. If the set
(default is 60 cycles) Over Timer cycle is reached, the
ORP2 output relay will de-energize. ORP2 will not ash
ORP digital display if ORP2 overfeed occurs).