2. Flow Cell with Flow Switch
a. An injecon-molded ow cell with integrated ow
switch houses the pH and ORP sensors, and partners with
the M820 controller to monitor the pH and ORP levels in
the water.
b. The ow switch veries that water is owing during a feed
cycle, and sends the controller instrucons to deacvate
the feed if water is not owing.
c. Operaon of this controller without a funconing ow-
switch will void the NSF Cercaon. Rounely check that
the ow-switch is funconing by closing the le valve on
the boom of the ow-cell (ow light should turn o).
3. pH and ORP Sensors
a. pH Sensor – standard (Use only IPS Controllers part # SXPH
to maintain NSF Cercaon)
b. ORP Planum Sensor – standard (Use only IPS Controllers
part # SXORP to maintain NSF Cercaon)
c. ORP Gold Sensor – for use with Salt Chlorine systems
(Use only IPS Controllers part # SXORP-G to maintain NSF
Cercaon)
4. Fings – tubing connectors (2) for tapping installaon of ow
cell input/output
5. In-line Filter with 2-way valves and mounng clamps (2)
6. Tubing – 25 feet of 3/8”
7. Mounng Board – ABS plasc with mounng holes and
stainless hardware (16” x 12” standard, 24” x 19” oponal for
mounng two chemical pumps)
8. Temperature Sensor – Senses the current water temperature
and displays the temperature in the display when in Temp
mode.
5
M820 pH/Dual ORP Controller Owner’s Manual