IRMA6
-SENSOR-HD-00-SWITCH-(IO)-00-(R)(1) Installation Manual | Released
Rev. 1.4 | 12/2020
4 / 27
1 IRMA 6 overview
Fig. 1: IRMA 6 in vehicles placement above doors, cross section in vehicle, door area in vehicle
The mounting height must not exceed 2.40 m (3 m in
preparation).
Table 1: Dimensions depending on door height
The door-to-IRMA 6 distance must not exceed 20 cm if the
installation height is less than 2 m.
Door height Covered door width Distance max
The inclination angle of IRMA 6 must not exceed 5°.
1.90 m 1.50 m 20 cm
For the relation between maximal distance
(door sensor), counting width and the door height see Table 1,
p. 4.
These values are standard values. In many cases wider ranges can
be covered. Please consult service@iris-sensing.com
.
2.00 m 1.65 m 20 cm
2.10 m 1.80 m 35 cm
2.20 m 1.95 m 40 cm