Utility Menu Options / Water Adjust Feature
15
14
Setup / Utility Menu Options
Default (DEFAULT _ ENTER): The Default utility feature enables
all user-dened setup parameters to be either erased and reset to
the factory default settings, or a complete system reset includ-
ing Location, History, and Sensor Pairing.*
•PresstheYES key to reset to the Factory Default settings.
See Default settings listed on page 12.
•PresstheNO key to return to the previous screen.
•Pressthe ERASE key to display the Erase All prompt screen.
• PresstheNO key to return to the Utility Menu screen.
•PresstheFACTORY key to return the Factory Reset screen.
•*Press the YES key to initiate the complete system reset.
Complete the procedure as indicated on the prompt screens.
Water Adjust Feature
The Water Adjust feature enables watering time to be ne-tuned
by applying small adjustments universally to all weather-regulated
stations.
From the Home screen, press the or key to access the
Water Adjust screen and to adjust scale. Press the SAVE key
to enter the change and return to the Home screen.
Note: If a particular watering zone appears over-or under-watered,
adjust the station run time in the controller watering program.
It is considered best practice to make adjustments in small increments;
allowing several days between changes to observe the results.
Freeze Temperature (threshold): The freeze sensor activation
threshold can be adjusted from 39° F (4° C), (default) down to 35° F
(2° C), or increased to 45° F (7° C), in 2° increments.
Important: Freeze sensor operation should be used only when the
watered area can be visually monitored. While the Freeze Sensor is
designed to cancel watering when air temperature is near freezing,
automatic watering can occur in certain circumstances. For example,
the air temperature may rise slightly above the sensor threshold, while
the temperature of the adjacent walkways remains below freezing.
Watering in this condition can result in unsafe walkway conditions. The Freeze Sensor feature is not intended to
replace any winterization procedures normally used to prevent freeze-related irrigation system damage.
Dry-out Days: This setting determines the minimum length of time that must elapse after the release of
a rain/freeze hold, and automatic watering can resume. By default, the dry-out period is ½ day (12 hours),
and is adjustable from 0 to 3 days in ½-day increments.
Utility Menu Options
The following Utility features are accessed through the Utility
Menu screen (MENU _ UTILITY _ ENTER).
Display Contrast (CONTRAST _ ENTER): The LCD screen contrast
is factory set at the midpoint adjustment range. Contrast intensity
can be adjusted incrementally to the preferred level.
Units: (UNITS _ ENTER): By default, all units of measure are dis-
played in English standard format, and time in 12-hour (a.m./p.m.)
format. Metric units of measure, and/or 24-hour (military time)
formats can be selected as preferred.
ET Setup
Freeze Temperature 39F
Dry Out (days) 0.0
SAVE
3 of 3
BACKCANCEL NEXT
Utility Menu
Contrast
Units
History
Loader
About
Default
EXIT ENTER
Reset To
Factory Defaults?
YES NOERASE
WATER ADJUST
MORELESS
SAVE CANCEL
Erase All?
All data will be lost!
YES NOFACTORY