3.12 TRANSDUCERS.
We have a set of optional transducers, linear and rotating. Linear transducers have different strokes,
and also different IP protections: low for the TLH series, high for the LWG series. A mounting kit
is also available. The table summarizes characteristics and codes.
TYPE
DESCRIPTION
STROKE (mm)
CODE
LINEAR
TLH150
150
PII11166
LINEAR
TLH225
225
PII12166
LINEAR
TLH500
500
PII13166
LINEAR
LWG150
150
PII26166
LINEAR
LWG 225
225
PII27166
LINEAR
LWG 500
500
PII28166
ROTATING
-
-
PII14166
-
MOUNTING
KIT
-
PII16166
The mounting kit includes the following materials:
. N. 1 Magnetic support (1). The magnetic base is 50 x 80 mm;
. N. 1 Adaptive arm (2). The length of the two parts are 130 and 160 mm, the maximum distance is
290 mm;
. N. 1 Small mechanical clamp (3). The maximum opening is 40 mm;
. N. 1 Big mechanical clamp (4). The maximum opening is 65 mm;
. N. 1 Support for the rotating transducer (5). Purpose of the magnetic support or clamps is to
provide the base for the arm. To the other end of the arm is screwed to rotating transducer support.
The kit is included into a plastic transport case. The following picture shows the open case.