EasyManua.ls Logo

Iskra WM3M4 - Dataset Format

Iskra WM3M4
57 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DIGITAL SIGNATURE (VALID ONLY FOR WM3M4C)
User’s Manual WM3M4 &WM3M4C
39
6.5.15 Dataset format
Format is compliant with OCMF v1.0.
Energy meter requires following fields in dataset:
{
"FV":"1.0",
"GI":"",
"GS":"",
"PG":"",
"MV":"",
"MM":"",
"MS":"",
"MF":"",
"IS":true,
"IF":[],
"IT":"NONE",
"ID":"",
"CT":"EVSEID",
"CI":"",
"RD":[]
}
Warning: JSON names must be in specified order and without whitespaces. Downloaded message
should look like:
{"FV":"1.0","GI":"","GS":"","PG":"","MV":"","MM":"","MS":"","MF":"","IS":true,"IF":[],"IT":"NONE","ID
":"","CT":"EVSEID","CI":"","RD":[]}
Example of valid JSON dataset (newlines are added for better readability):
{
"FV":"1.0",
"GI":"Gateway 1",
"GS":"123456789",
"PG":"",
"MV":"",
"MM":"",
"MS":"",
"MF": "",
"IS":true,
"IF":[
"RFID_PLAIN",
"OCPP_RS_TLS"
],
"IT":"ISO14443",
"ID":"1F2D3A4F5506C7",
"CT":"EVSEID",
"CI":"",
"RD":[]
}
Fields highlighted in green are mandatory.
Energy meter fills following values:
PG:”T<signature counter>” or “F<fiscal counter>” for fiscal readings
MV:“Iskra”
MM:”WM3M4”

Related product manuals