DIGITAL SIGNATURE (VALID ONLY FOR WM3M4C)
42
User’s Manual WM3M4 &WM3M4C
6.5.17 Measurements table
Control unit can check measurements and statuses during the charging process
47000
Measurement status
T1
0
Idle
1
Active
2
Active after power failure
3
Active after reset
47001
47002
Duration
T3u
Seconds
47003
47004
Consumption
T_32U
Wh
47005
47006
Active Power Total (Pt)
T6
Reg (30140-30141)
47007
47008
Date and Time
T_Unix
47009
Tarrif changes count
T1
Command T
47010
Intermediate readings count
T1
Command C
47011
47012
Fiscal Readings count
T3u
Command f
47013
47014
Signatures count
(pagination)
T3
47015
47016
Start Timestamp
T_Unix
47017
47018
Start Counter value
T_32U
Wh
47019
47020
Stop Timestamp
T_Unix
47021
47022
Stop Counter value
T_32U
Wh
47023
47024
Tariff change Timestamp
T_Unix
47025
47026
Tariff change Counter value
T_32U
Wh
47027
47028
Intermediate Reading
Timestamp
T_Unix
47029
47030
Intermediate Reading
Counter value
T_32U
Wh
47031
47032
Fiscal Reading Timestamp
T_Unix
47033
47034
Fiscal Reading Counter value
T_32U
Wh
47035
47036
Hold measurement
Timestamp
T_Unix
47039
47040
Hold measurement
Timestamp
T_Unix
47041
47042
Hold measurement Counter
value
T_32U
Wh
47039
47040
Suspend Timestamp
T_Unix
47041
47042
Suspend Counter value
T_32U
Wh
Table 16: Measurements table