30
Electrical Specifications
Accuracy is ± (% reading + number of digits) at 23ºC ± 5ºC ,
less than 80% R.H.
(1) DC Volts
Range
Accuracy
103N 105N/106
400.0mV
±(0.3% + 2dgt) ±(0.3% + 2dgt)
4.000V
±(0.4% + 2dgt)
±(0.1% + 2dgt)
40.00V
400.0V
1000V
±(0.25% + 2dgt)
(2) AC Volts
Range
Accuracy
103N 105N/106
400.0mV
±(2.0% + 8dgt)* ±(2.0% + 8dgt)*
4.000V
±(1.3% + 5dgt)**
***
±(1.5% + 5dgt)
40Hz to 60Hz
±(1.0% + 5dgt)
61Hz to 1KHz
40.00V
400.0V
750V
±(1.5% + 5dgt)
40Hz to 60Hz
±(1.3% + 5dgt)
61Hz to 1KHz