13
ILCM 06 English
Accuracy is ±(% reading + number of digits) at
23°C ± 5°C < 80%RH.
* There is a little rolling within ±3 digits.
2%+6D(0~30A), 30%+6D(30~100A)
0.04% typical value.
* There is a little rolling within ±3 digits.
approx. –24dB/oct
100Hz
6mA * 0.001mA
0 ~ 50A: ±(1% + 3D))
50 ~ 60A: ±(5% + 6D)
60 ~ 100A: ±(8% + 6D)
60mA 0.01mA
600mA 0.1mA
6A 0.001A
60A 0.01A
100A 0.1A
6mA * 0.001mA
0 ~ 50A: ±(2% + 6D))
50 ~ 60A: ±(6% + 8D)
60 ~ 100A: ±(9% + 8D)
60mA 0.01mA
600mA 0.1mA
6A 0.001A
60A 0.01A
100A 0.1A