Fire-Lite Application - Flush Wall Finish Detail
Fire-Lite replaces are designed to be installed so that the rough front face of the rebox and damper plate project into the room
approximately one-half inch (1/2”) beyond the face of the rough framing members that create the room’s wall surface. The smoke
dome unit sits two and three-fourths inches (2 3/4”) back from the rough face of the rebox and damper plate. This set back dimen-
sion allows for one and one-half inch (1 1/2”) framing plus one-half inch (1/2”) thick wall board to pass in front of the smoke dome
and at the same time align ush with the room face of the Fire-Lite damper plate.
Clearance to Drywall:
Drywall can be placed directly in contact with the front of the rebox and smoke dome. Set in this position, framing and wall board
are kept to the required eight inches (8”) above the rebox opening top. (Figure 132)
Important: Do not build a frame wall in front of the MAGNUM rebox and damper plate. (Figure 133)
FIGURE 133
FIGURE 132