The UVF11 series are NOT intended to treat water with obvious contamination or intentional
source, such as raw sewage; nor is the unit intended to convert wastewater to safe drinking
water.
Precautions
Warning:
- Changes or modifications made to this system without the manufacturer's consent could
render the system unsafe for operation and may void the manufacturer's warranty.
- Do not operate the UV Lamp when removed from the reactor chamber, as this may cause
exposure to dangerous UV radiation.
• To avoid possible electric shock, special care should be taken since water is near the
electrical equipment.
• Do not operate the unit if it has a damaged cord or plug, malfunctioning, or has been
dropped or damaged in any manner.
• This unit is only designed for potable water applications. Using attachments not
recommended or sold by the manufacturer may cause unsafe conditions.
• Please do not install this product outside or at a place where it is exposed to direct
sunlight or freezing temperature.
• Please install this product at a place where it is easy to access and maintain.
• The UV lamp contains mercury. If the lamp breaks, avoid inhalation or ingestion the
debris and avoid exposure to eyes and skin. Never use a vacuum cleaner to clean up a
broken lamp, which may scatter the spilled mercury. Follow local regulations and
guidelines for the removal and disposal of mercury waste.
Installation
Note:
• Make sure the quartz tube and UV Lamp are clean before installation. Use alcohol or
mild detergent to clean if necessary.
• The UVF11 series are designed for continuous operation. Frequent switching will reduce
the UV radiation and service life.
• Always turn the main power off before any actions on the UV system.
• The UV system should be installed after the filters as the last stage.
• Keep the UV system away from children to avoid potential injury.
Step 1. Remove both the open end nut and closed-end nut from the reactor chamber.
www.123filter.com | (678) 261-7611 | support@123filter.com Page 7