Troubleshooting
ISSUE POSSIBLE CAUSE POSSIBLE SOLUTION
The control valve does
not work
Connect the power supply.
Repair or replace the socket.
Wait for power to be restored.
Replace the transformer.
Incorrect regeneration
time
Recalibrate the time according to
the instructions.
Leaking water
Tighten the connection or
reconnect.
Noise in equipment
Backwash again, exhaust air.
The effluent contains
bubbles
Backwash again, exhaust air.
No softened water
Add salt.
Remove blockages.
Increase the inlet water
pressure, which should be
greater than 20 psi.
Check all components of the
brine
suction pipe and eliminate
the leakage point.
See the "No salt absorption"
troubleshooting method for
details.
No salt absorption
Check controller power.
Clean the injector net.
Disassemble the injector net
and rinse with water to remove
blockages, then reinstall.
Remove the blockage or
replace the brine valve.
Remove the brine suction
orifice plate and rinse with
water to remove the blockage,
then reinstall.
Backwash flow is too
high or too low
Replace with suitable flow
control.
Remove foreign objects.
The effluent water has
Contact iSpring.
Page 25 www.123filter.com | (678) 261-7611 | support@123filter.com