Safety Instructions
To reduce the risk of electrical shock, the system must be installed by a qualified installer
or dealer.
Please read the instruction manual in it’s entirety before installing.
Please do not attempt to remove or repair your existing system or the Intrasonic
Technology Retro system. Call a qualified installer or dealer.
The apparatus shall not be exposed to dripping or splashing from liquids. No objects filled
with liquids , such as vases shall be placed on the apparatus.
Before performing any work on the existing system or the Intrasonic Technology Retro
system, make sure the power is turned off.
Do not expose outdoor units like the Patio or Door unit to direct water exposure. Direct
water exposure could cause premature failure and performance issues.
Use only Intrasonic Technology certified replace parts.
NOTE: THE RETRO-M MASTER MUST BE INSTALLED IN AN EXISTING APPROVED
INTERCOM HOUSING OR THE I1000H HOUSING TO MEET LOCAL ELECTRICAL
CODES AND SAFETY REQUIREMENTS.
ATTENTION - POUR RÉDUIRE LE RISQUE DE CHOC ÉLECTRIQUE, NE PAS RETIRER LE
COUVERCLE (OU L'ARRIÈRE). NON UTILISATEUR À L'INTÉRIEUR. VOIR À UN PERSONNEL
QUALIFIÉ.
CAUTION - TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR
BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER TO QUALIFIED SERVICE
PERSONNEL.
Don’ts
Expose any parts of the Intrasonic Technology Retro system to moisture.
Install any room, patio, or door station closer than 10 feet from each other or back to back
on the same wall. This could cause system feedback.
Perform any work on the system without turning the system power off first.
Do’s
Use a qualified installer or dealer.
Use with Intrasonic Technology approved products.
Use a dedicated 110VAC line to the master. Not using a dedicated line could cause
popping, humming or buzzing noises in the system.
Use a dedicated line with its own disconnect device.
Locate away from any heat sources.
Label all wires.
Only one auxiliary input can be installed per system.
Wiring must follow NEC 640 and 725 for audio wiring.
All holes must be filled with wires and any remaining area must be filled and sealed.
Warnings
An apparatus with Class 1 construction shall be connected to a MAINS socket outlet
with a protective earthing connection.
Un appareil avec la construction de la classe 1 sera relié à une sortie de douille de
FORCES à un raccordement
To prevent injury, this apparatus must be securely attached to the floor/wall in
accordance with the installation instructions.
Pour empêcher des dommages, cet appareil doit être solidement fixé au
plancher/au mur selon les instructions
Intrasonic Technology, Inc. 610 Presidential Dr. Suite 104 Richardson, Texas 75081 877-435-0670