Technical Specification
Parameter IT-M7721
Crest factor 3
Line Regulation *3
≤0.06%
Load Regulation *3
≤0.15%
Output voltage
(VAC)
Resolution 0.1V
Accuracy ±(0.2%+0.2% F.S.)
Frequency
Resolution 0.1Hz
Accuracy
±0.1%
Phase angle de-
gree range
Resolution 0.1°
Accuracy
0.5°
DC offset value 20mVdc
Efficiency 75% (Typical)
DC Output
Max. output power
300W
Max. output voltage
±400Vdc
Maximum output current (rms)
±3A
DC voltage Accuracy ±(0.2%+0.2% F.S.)
Dynamic response time (Full load of
10~90%)
≤0.5ms
Meter
AC Voltage
Range
0300V
Resolution 0.1V
Accuracy ±(0.25%+0.25% F.S.)
AC current (rms,
High range)
Range
0.13A
Resolution 10mA
Accuracy ±(0.5%+0.5% F.S.)
AC current (rms,
low range at
100HZ)
Range
0.11250 mA
Resolution 0.1mA
Accuracy ±(0.25%+0.25% F.S.)
AC current (peak)
Range
04.25A
Resolution 10mA
Accuracy ±(0.4%+0.8% F.S.)
DC voltage Accuracy ±(0.25%+0.25% F.S.)