Technical Specification
Parameter IT6012C-800-50
±(%of Output+Offset)
Current ≤0.05%FS
Setup Resolution
Voltage
0.01V
Current 0.01A
Power 0.001kW
Resistance 0.001Ω
Read Back Resolution
Voltage
0.01V
Current 0.01A
Power 0.001kW
Resistance 0.001Ω
Setup Accuracy (within 12
months, 25℃ ±5℃) ±(%
ofOutput+Offset)
Voltage
≤0.02% + 0.02%FS
Current ≤0.1% + 0.1%FS
Power ≤0.5% + 0.5%FS
Resistance ≤1% + 1%FS
Read Back Accuracy (within
12 months, 25℃ ±5℃) ±(%
of Output+Offset)
Voltage
≤0.02% + 0.02%FS
Current ≤0.1% + 0.1%FS
Power ≤0.5% + 0.5%FS
Resistance ≤1% + 1%FS
Ripple Voltage ≤800mVpp(MAX:≤1.2Vpp)
(20Hz -20MHz)
Current ≤0.1%FS RMS
Setup Temperature
Coefficient
Voltage
≤50PPM/℃
±(%of Output/℃+Offset)
Current ≤200PPM/℃
Read Back Temperature
Coefficient
Voltage
≤50PPM/℃
±(%of Output/℃+Offset)
Current ≤200PPM/℃
Rise Time( no load ) Voltage
≤15ms
Rise Time( full load ) Voltage
≤30ms
Fall Time( no load ) Voltage
≤30ms
Fall Time( full load ) Voltage
≤15ms
Transient Response Time Voltage
≤2ms
AC Input
Voltage (Three-
phase four-wire) 1
198V~264V (Derating 50%) 342V~528V
Maximum Input
Current
L1,L2/20A;L3/34A
Copyright © Itech Electronic Co., Ltd.