EasyManua.ls Logo

ITech IT6502D

ITech IT6502D
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command syntaxSTATus:QUEStionable:ENABle <NR2>
Parameter:0~65535
Default setRefer to *PSC command
ExampleSTATus:QUEStionable:ENABle 128
Query syntaxSTATus:QUEStionable:ENABle
Returned parameter<NR2>
STATus: QUEStionable:NTRansition
This command is used to edit the negative transition trigger register of operation event. The
parameter determines which bits of operation event register is 1 will cause the OPER of
status byte register to be 1.
Command syntaxSTATus: QUEStionable:NTRansition <NR1>
Parameter:0~255
ExampleSTATus: QUEStionable:NTRansition 128
Query syntaxSTATus: QUEStionable:NTRansition
STATus: QUEStionable:PTRansition
This command is used to edit the positive transition trigger register of operation event. The
parameter determines which bits of operation event register is 1 will cause the OPER of
status byte register to be 1.
Command syntaxSTATus: QUEStionable:PTRansition <NR1>
Parameter:0~255
ExampleSTATus: QUEStionable:PTRansition 128
Query syntaxSTATus: QUEStionable:PTRansition
STATus:OPERation[:EVENt]?
This command can read the parameter from operation event register. After executing this
order, operation event register is reset.
Query syntaxSTATus: OPERation [:EVENt]?
Parameter: None
Returned parameter<NR1>

Other manuals for ITech IT6502D

Related product manuals