Function and Features
Copyright ©ITECH Electronic Co., Ltd. 14
Group = 0
0:represents 1-10sets
1:represents:11-20sets,
by parity of reasoning
Buzzer
BUZZER STATE
Set the buzzer function
On(Def)
enable the buzzer function
Off
disable the buzzer function
Communication
COMMUNICATION
Select the communication interface
RS232(Def)
Select RS232 communication interface
4800, 8, None parity 1 , Addr...
9600 Odd parity (0~31)
19200
Even parity
38400
57600
115200
USB
Select USB communication interface
GPIB
Select GPIB communication interface
Addr= 0 set the communication address
RS485
Select RS485 communication interface
4800, 8, None parity, 1 , Addr...
9600 Odd parity (0~31)
19200 Even parity
38400
57600
115200
ReturnMeter
RETURN METER
Enables automatic delay to switch display
from setting to measured value (meter).
Off(Def)
Automatically Return Meter function
disabled.
Delay
The function of Automatically return meter
after 5s enabled.
P-Out
P-On Output
Set the output status of power supply power
on
Off(Def)
After power on, the power supply output
status will be Off.
Last
The output status of power supply will be
same as last output status before power off.
Sense-Protect Sense Protect
Enable sense protection function
Enable
Disable sense protection function
Disable(Def)
Enables dummy load to increase speed of
voltage fall time.