NOTE
Pressing button can enable you to quit any function setting.
Maximum voltage set (MAX VOLT)
The range of setting voltage is from 0V to rated voltage. You can press
(Shift) + (Menu) button to enter the menu, then press 、 key to
select >MAX VOLT item. Press button to confirm. After you set the
max voltage value, the output voltage value can only be set within the max
voltage. The default max voltage value is the rated value.
Charge-mode function set (CHANG)
This function is used for IT6726C power to battery charging. When ON option is
selected, the power output is turned off after completing the battery charge,
meanwhile the power will not reverse current, that is to say the battery will not
discharge. When OFF option is selected, the power will reverse current after
the battery charge finished and the battery will discharge. The default setting is
OFF option.
NOTE
In addition to providing a battery charge, IT6726C power is used for other work, please
select OFF option for CHANG function. If the function is selected for CHANG ON option,
when the power output is turned off, fall-time of the power becomes very long.
Only IT6726C Power contains CHANG function.
Power-on parameters set (P-MEM)
This item can set power on parameters. If you select RESET item, then all the
parameters will be initialized to the factory setting. Output voltage and current
will always be 0V/max rated current; if set to Keep, the output value will be the
same with last power off state. The default setting is RESET item.
Power On Output State (P-OUT)
This item can set the power on output state. If you select KEEP item, that
indicates the power on output state is the same with output state before this
item is set. If you select Off item, unit will automatically in off mode when you