Function and Features 
  Copyright ©ITECH Electronic Co., Ltd.  27 
 
Before using analog function, you need to turn on this function in the menu. You 
need to set the Ext-C item in the System menu, and select ANA to enable the 
external analog control function; select DIGIT to enable the external digital 
control function. 
The external analog interface terminals: REF_10V , Vs/D0, Is/D1 , D2, 
ON/OFF , Vm , Im , NULL , GND correspond to the reference voltage, voltage 
control/digital D0, current control/digital D1, digital D2, output on and off control, 
voltage monitoring, current monitoring, null pin, and ground. 
  External analog control interface usage. 
You can use three channels of 0~10V analog signal to control voltage, current 
and output on/off respectively; and two channels of 0~10V analog signal to 
monitor the voltage and current output of power supply. 
Detailed terminal descriptions are listed in the table below. 
The power supply itself outputs a 10V reference voltage, which 
can be connected to a resistor for voltage dividing and used for 
Pin2 
Vs (voltage 
setting)/D0 
Voltage control as well as digital input D0 bit. 
The voltage control terminal, with an analog input range of 
0~10V, can be used to adjust the voltage between 0~voltage 
full scale. Taking the IT6942B as an example, when the voltage 
input to this terminal is 5V, the corresponding output voltage of 
the IT6942B should be 30V. 
 
setting)/D1 
Current control terminal and digital input D1 bit. 
The  current 
control terminal, with an analog input range of 
0~10V, can be used to adjust the current between 0~current full 
scale, take IT6942B as an example, when the input voltage of 
this terminal is 1V, the corresponding output current of IT6942B 
should be 1.5A. 
2
Digital input D2 bit, input 0V (means digital quantity 0) or 10V 
(means digital quantity 1). 
D2D1D0 combination can input digital quantity 0~7, digital 
quantity 0 is invalid input, input digital quantity 1~7 means recall 
the parameter in the storage area of Group1~7. 
Output on/off control, input analog is 0V or 10V, when input 0V, 
power output state is OFF, when input 10V, power output state 
 
Monitor the output voltage.