SOURce Subsystem
Copyright © Itech Electronic Co., Ltd. 93
Unit
seconds
*RST Value
0
Examples
POW:PROT:DEL 5
Query Syntax
[SOURce:]POWer:PROTection:DELay? [ MINimum | MAXimum | DEFault ]
Returned Parameters
<NR1>
Related Commands
POW:PROT
[SOURce:]POWer:CONFig
This command sets the hard power protection level.
Command Syntax
[SOURce:]POWer:CONFig[:LEVel] <NRf+>
Parameters
0 through MAX | MINimum | MAXimum | DEFault
Unit
W (power)
Returned Parameters
MAXimum
Examples
POW:CONFig 100
Query Syntax
[SOURce:]POWer:CONFig[:LEVel]?
Returned Parameters
<NR3>