Measure the spin time (ST) until the tur-
bine wheel stops.
See Annex 5 for typical values of spin
time.
The following recommendations have to
be observed for repair:
In case of use with aggressive or danger-
ous gas, it may be necessary to send a
safety statement with the meter, detail-
ing the type of Gas that has been mea-
sured.
Some gas may still be present inside the
meter and the pipe; therefore sufficient
ventilation is required.
Repairs and maintenance must be done
by trained or qualified personal. Afte-
rwards a tightness test with 1.1 x PS
(Pmax) must be performed.
When changing pressure-bearing parts,
ensure that spare parts which comply
with the PED are used.
If used with wet gas, internal and exter-
nal effect of corrosion has to be checked
regularly and in case of severe corrosion,
the meter must be replaced.
Use solvent and alcohol free cleaning
product to clean the meter.