72
SECTION 3 - INDUSTRIAL APPLICATION
VECTOR 8 ENGINES
Base - April 2006 Print P2D32V001E
Symptom
Visible
trouble
Possible cause Repair Notes
Attributable to malfunctioning in the fuel supply:
Indicators on - No No fuel in the tank or defect ascribable to
Fill up the tank and check why there is no fuel.
In order to ascribe or exclude level sensor,
suction de
ice or fuel le
el indicator defect
startup sign
asuctiondefect
Chec
suction de
ice and remo
ewhate
er
caused clogging.
check fuel level in the tank by relevant level
indicator.
Indicators on Excessive water in the prefilter
After checking is there is any condensate
exhaust as described on the ordinary
maintenance manual or during sensor
inspection.
Therefore first check the sensor connection
and replace the sensor if trouble is due to it.
The engine will not
start.
Indicators on Filters clogged
After checking the conditions of cartridge
clogging replace them or check the sensor.
Afterwards check the connection and if the
trouble is due to the sensor replace it.
Fuel leaking from
the pipes.
Rupture of the supply circuit pipes Check and replace the damaged part.
Total absence of
pressure in the rail
Air in the fuel circuit
Check the fuel supply circuit on low pressure
side.
Check the fuel supply circuit on high pressure
side.
Check that there is no air in the prefilters and
in the fine filters.
Check that there is no air in the rail and in the
high pressure pump bleed.
If the trouble persists with suitable pressure
gauge check the high and low pressure pump
inlet and outlet pressures.
Flow regulating valve (M-promp) locked
closed.
Replace M-promp