9. Product Specifications
9.1 Delivery forms
Programat CS4
Power cord
Sintering Furnace Temperature Checking Set Starter Kit
Operating Instructions
Sinter tray
Sinter tray fork
IPS e.max Speed Crystallization Tray
USB download cable
var. accessories
9.2 Technical data
Power supply 118–240 V / 50–60 Hz
Overvoltage category II
Contamination level 2
Acceptable voltage fluctuations ± 10 %
Max. power consumption 16 A at 118 V
8 A at 240 V
Electric fuses 250 V / T16 A high breaking (heating circuit)
Dimensions of electric fuses 250 V / T16 A high breaking (heating circuit)
Dimensions of the closed furnace Depth: 430 mm
Width: 310 mm / 390 mm (with cooling tray)
Height: 570 mm
Usable size of the firing chamber Diameter: 80 mm
Height: 80 mm
Max. firing temperature 1600 °C/2912 °F
Weight Furnace base: 10 kg
Furnace head: 17 kg
Safety notes
The sinter furnace complies with the following standards:
IEC 61010-1: 2010
EN 61010-1: 2010
UL 61010-1: 2012-2015
CSA 61010-1: 2012 – 2015
IEC 61010-2-010: 2014
EN 61010-2-010: 2014
UL 61010-2-010: 2015
CSA 61010-2-010: 2015
Radio protection / electromagnetic compatibility EMC tested
9.3 Acceptable operating conditions
Acceptable ambient temperature range: +5 °C to +40 °C (+41 °F to +104 °F)
Acceptable humidity range: Relative humidity 80% for temperatures up to 31 °C/88 °F
gradually decreasing to 50% relative humidity at 40 °C/104 °F,
condensation excluded.
Acceptable ambient pressure: The furnace is tested for use at altitudes of up to 2000 m
above sea level.
9.4 Acceptable transportation and storage conditions
Acceptable temperature range: –20 °C to +65 °C (–4 °F to 149 °F)
Acceptable humidity range: Max. 80% relative humidity
Acceptable ambient pressure: 500 mbar to 1060 mbar
Use only the original packaging together with the corresponding foam material for shipping purposes.