BATTERY
The DataLift is equipped with maintenance-free AGM lead battery 2 x 12 V/36Ah. These batteries are
maintenance-free and must not be relled with water.
Note: Please observe the maximum operating temperature of the battery.
CHARGING THE BATTERY
Only charge the battery in well ventilated places!
The DataLift should be charged after each use and in best case it is always connected to power when
not in use.
Always disconnect the charger before use!
If the battery is completely discharged, the charging process takes about 6 hours. Avoid discharging
the battery by more than 80% of its charge capacity to ensure a long battery life.
REPLACEMENT OF THE BATTERY
Only qualied personnel should repair the battery.
Battery recycling must comply with local laws and regulations. Please comply with these regulations.
Please be sure to follow the operating instructions. Improper handling, e.g., use near re, can cause
an explosion! For this reason, the storage of ammable materials or ammable liquids in the battery
charging area is prohibited. Smoking is prohibited and the area must be well ventilated.
Before charging or installing the battery, park the DataLift safely (parking position).
Only the use of the sealed lead acid battery is allowed, the additional battery weight has an inuence on
the behaviour of the vehicle.
Open the back cover according to the section “Opening of the Back Cover”.
Then loosen the screws (negative terminal indicator as ‚-‘), then the screws (positive terminal indicator
as ‚+‘) and the wiring harness. Next, open the battery holder straps. When removing the battery, do not
short circuit the battery! For reassembly, reverse the order. Connect the positive pole of the battery to
prevent damage to the DataLift.