18
OPERATING MANUAL – DataLift 250
TROUBLESHOOTING
Problem Reason Solution
No response
Fuse is out Replace fuse
Main switch Enable main switch
Remote cable broken Replace remote control
Emergency stop
Pull emergency reset button
to reset
Winch motor is broken Replace motor
Controller is broken Replace controller
Not lifting
Top limit reached Lower table
Collision on top sensor
Check top sensor and go down
before again going up
Not lowering Collision with obstacle
Go up again and remove
obstacle
Lifting only a few seconds then
stops
Overload Unload ballast
Battery is empty Charge battery to full
Lowering without action Winch brake worn Replace winch
Suddenly lifting
Broken spiral cable of the
remote
Remove main switch key and
replace remote control before
starting again
Broken controller Replace controller
Not charging
Fault in calbe / grid connection Check LEDs on charger
Charger fuse is out Replace fuse
Locking mechanism does not
work
Stuck bowden cable Remove dirt and check cables
Locking bolt/clevis damaged Adjust or replace
Brake does not work
Bolts are broken
Replace connection bolt from
foot lever to axle
Brake pad is worn Replace wheel and bracket
Tire is worn Replace wheel and bracket